Disposable Classic Surgical Trocar - CFDA Certified
● Design: Integrated valve system designed for superior air leakage control and maintaining pneumoperitoneum.
● Specifications: Available in standard 100mm length with 5mm, 10mm, and 12mm diameter options.
● Safety: EO sterilized and single-use only to ensure maximum hygiene and prevent cross-infection.
● Certifications: CFDA Certified; OEM services available to meet specific clinical requirements.
Description
Classic Access Cannulas for Laparoscopic Entry Management
The Disposable Classic Surgical Trocar is a fundamental clinical-grade access instrument engineered to establish a highly stable, controlled, and fluid-resistant entry pathway for laparoscopic surgical tools, grasping instruments, articulating clippers, and fiber-optic endoscopes during advanced minimally invasive surgery (MIS). Incorporating a time-tested traditional structural configuration alongside an integrated valve system, it delivers high-performance air leakage control during instrument insertion and rapid tool exchanges, helping clinical teams preserve steady intra-abdominal pneumoperitoneum parameters across routine surgical workflows.
Manufactured in a standardized 100 mm effective working length, our classic trocar arrays provide versatile, procurement-friendly instrument cross-compatibility via three precise core diameter variations: 5 mm, 10 mm, and 12 mm. This dimensional range supports standard operating theater insertion steps while facilitating streamlined SKU management for large-scale procurement programs, hospital supply chains, and private label distributor networks worldwide.
Typical Clinical Applications
Our single-use classic access devices provide dependable, repeatable structural entry across standard laparoscopic surgical environments:
- General Laparoscopic Surgery – Primary access ports for cholecystectomy, bariatric, and abdominal exploration procedures.
- Laparoscopic Abdominal Procedures – Establishing reliable instrument paths during appendectomy and multi-quadrant hernia repairs.
- Gynecological Laparoscopy – Supporting safe entry lines for pelvic cavity camera visualization, hysterectomy, and myomectomy.
- Urological Laparoscopy – Providing consistent cannula channels during minimally invasive nephrectomy and prostate access steps.
- Routine MIS Workflows – Facilitating standardization protocols across standard high-volume day surgery centers.
- Standard Instrument Access Setup – Ensuring broad compatibility with a wide selection of laparoscopic tool brands.
Compatible Instruments & Operating Room Setups
The Senmed standardized cannula framework is engineered to seamlessly guide standard instrumentation lines, matching widespread operating theater configurations:
- Standard single-use and reusable laparoscopic trocars and multi-size access kits.
- Laparoscopic grasping forceps, dissectors, and hemostatic probe tools.
- Laparoscopic surgical scissors, curved dissectors, and titanium clip appliers.
- High-definition rigid laparoscopic endoscopes and optical lens modules.
- Conventional medical video carts and advanced laparoscopic visualization systems.
- Standard automated CO2 insufflator units and gas delivery tubes for pneumoperitoneum.
Supplied as an individual-pouch EO sterilized, single-use surgical device, this premium laparoscopic trocar line fulfills strict hospital hygiene frameworks and cross-infection control requirements. It complies fully with CFDA certified manufacturing paradigms, offering international contract customers comprehensive private brand labeling and tailored global distributor program options.
Feature
- Time-Tested Classic Trocar Architecture: Traditional structural layout provides an uncompromised, mechanically stable entry system for reliable laparoscopic channel creation.
- High-Efficiency Integrated Valve System: Specialized built-in valve configuration seals tightly against tool shafts, providing exceptional air leakage control during instrument modifications.
- Standardized Length Dimension Matrix: Uniform 100mm sleeve profiling combined with 5mm, 10mm, and 12mm diameter specifications satisfies most routine minimally invasive access needs.
- Absolute Sterile EO Validation: Pre-sterilized via環氧乙烷 (Ethylene Oxide) gas and structured as a disposable item to eliminate hospital validation overheads and cross-infection variables.
- Scalable Regulatory and OEM Sourcing: Holds active, documented CFDA certification parameters, optimized for private label branding services and global high-volume distributor logistics.
Specification
Disposable Classic Surgical Trocar Ordering Specifications:
| Item Number | Technical Diameter & Cannula Length Configuration Description | Standard Case Package |
|---|---|---|
| ATS-0091-000 | Classic Surgical Trocar, Standard Entry Profile, 5mm Diameter x 100mm Length | 40 PCS / CTN |
| ATS-0092-000 | Classic Surgical Trocar, Standard Entry Profile, 10mm Diameter x 100mm Length | 24 PCS / CTN |
| ATS-0093-000 | Classic Surgical Trocar, Large-Bore Access Profile, 12mm Diameter x 100mm Length | 24 PCS / CTN |